
HMO Conversion Drawings in Hanwell W7
Fixed-fee, MCIAT-chartered hmo conversion drawings for Hanwell (W7) homeowners — London Borough of Ealing validation and local constraints handled from the start.
Hanwell (W7) keeps a genuine village feel around its green, with historic buildings on spacious, tree-filled plots giving way to consistent Victorian and Edwardian terraces on the surrounding streets. Rear and loft projects follow the familiar Ealing terrace pattern on most roads, but the conservation-area picture is more layered than it first looks.
The Hanwell Village Green conservation area protects the older core, while the St Mark's Church and Canal area runs along the Brent and the Grand Union Canal to the south. We establish which context a Hanwell property sits in — ordinary terrace, protected village core or canal-side setting — before drawing to the borough's guidance.


Planning in Hanwell (W7): what to know before you apply
W7 carries no householder Article 4 direction affecting typical work, so many Hanwell houses retain permitted development rights for rear and loft projects — but the Hanwell Village Green, St Mark's Church and Canal, and Hanwell Cemeteries conservation areas are the exceptions where character, plots and trees are actively protected. London Borough of Ealing does not publish an Article 4 schedule to the national open-data register, so we verify the current position with the council before advising.
Typical Hanwell housing stock
Late-Victorian and Edwardian terraces and semi-detached houses across the district, older historic buildings on spacious plots around the village green, and larger houses in the Golden Manor enclave.
Streets we regularly draw for in Hanwell
Church Road · Boston Road · Golden Manor · Cuckoo Avenue · Green Lane
HMO Conversion Drawings for Hanwell (W7) homes: the package and the process
Every hmo conversion drawings we prepare for an Hanwell property is drawn to London Borough of Ealing’s validation standards and tuned to the W7 constraints above. Here is what the drawing package covers and how the process runs from first survey to approval.
A House in Multiple Occupation (HMO) is a property let to three or more unrelated occupants sharing kitchen, bathroom or living facilities. A small HMO — three to six sharers — normally falls into Use Class C4, while a large HMO of seven or more occupants is sui generis, sitting entirely outside the Use Classes Order. Both routes trigger licensing requirements, and in many London boroughs an Article 4 direction removes the usual permitted development right to convert a family home (C3) into a small HMO (C4), meaning full planning permission is needed even for a straightforward conversion.
DrawingsDirect draws HMO conversions to the standard your borough's planning and licensing teams both expect — minimum room sizes, amenity provision, fire safety and means of escape — so one set of drawings supports both the planning application, where needed, and the licensing submission. We check whether an Article 4 direction applies to your property before you commit to a route, and coordinate fire safety and structural detail in-house.
C4 small HMO or sui generis large HMO — which applies to your property?
The distinction matters because it decides which rules apply. A small HMO housing three to six unrelated sharers who share amenities is Class C4. A large HMO of seven or more occupants is sui generis and always needs planning permission, since sui generis uses sit outside the permitted development system entirely. The line also shifts with occupancy — a property let to six sharers today can tip into sui generis territory the moment a seventh tenancy is signed, which changes the planning position even though nothing about the building itself has changed. We assess your proposed occupancy and layout against both definitions before drawing, so the application matches how the property will actually be let.
Do I need planning permission for an HMO conversion in London?
Converting a family home (C3) into a small HMO (C4) is technically permitted development under national rules, but a large number of London boroughs have made an Article 4 direction that removes this right across all or part of the borough — meaning a full planning application is required even for a small, compliant HMO. Article 4 directions vary street by street in some boroughs, so two similar houses a few doors apart can sit on opposite sides of the line. Any large HMO (sui generis) needs planning permission everywhere, regardless of Article 4. We check your specific address against the relevant borough's Article 4 direction before recommending a route, since guessing wrong wastes both time and application fees.
| Factor | C4 small HMO (3–6 sharers) | Sui generis large HMO (7+) |
|---|---|---|
| Use class | C4 | Sui generis |
| Planning permission | Often needed due to Article 4 directions in most boroughs | Always needed |
| Licensing | Mandatory if 5+ occupants; additional licensing in many boroughs | Mandatory |
| Typical drawing package | From £1,400 | Full planning + building regs, from £2,200 |
HMO Conversion Drawings in Hanwell W7 — FAQs
How much do HMO conversion drawings cost in London?+
Is HMO conversion permitted development in London?+
Do I need a licence as well as planning permission?+
Do I need an architect for an HMO conversion?+
How long do HMO conversion drawings take?+
Do I need planning permission for a rear extension in Ealing?+
What extra control applies in Bedford Park?+
How long does Ealing Council take to decide a householder application?+
Can you help with a loft conversion on a 1930s Ealing semi?+
How much do planning drawings cost in Ealing?+
Get your free Hanwell planning assessment
Tell us your Hanwell (W7) address and ambition — we'll confirm feasibility, local constraints and a fixed fee within one working day.