Flat Conversion Drawings in Greenwich SE10
Fixed-fee, MCIAT-chartered flat conversion drawings for Greenwich (SE10) homeowners — Royal Borough of Greenwich validation and local constraints handled from the start.
Greenwich (SE10) is among the most heritage-sensitive places to build in London: most of its period housing sits within one of the Royal Borough's conservation areas — West Greenwich, Greenwich Park, East Greenwich or the Ashburnham Triangle — and three of those carry Article 4 directions that pull nearly all external work into the planning system. Side-return and rear extensions on the Victorian and Georgian terraces are the staple, but they are judged carefully on materials, proportion and detail.
SE10 also sits within, or beside, the Maritime Greenwich World Heritage Site: the inscribed core is the Old Royal Naval College, Queen's House, Royal Observatory and Cutty Sark, with the surrounding streets in the buffer zone. That means townscape and setting weigh heavily on how schemes are assessed. We check exactly which conservation area — and which Article 4 direction — applies to a Greenwich address before advising on a permitted-development or full-application route.


Planning in Greenwich (SE10): what to know before you apply
Most SE10 houses fall inside the West Greenwich, Greenwich Park, East Greenwich or Ashburnham Triangle conservation areas, and the first three carry Article 4 directions removing permitted-development rights for re-roofing, windows, doors and other external changes. The Maritime Greenwich World Heritage Site and its buffer zone add further townscape scrutiny. We confirm the conservation area and Article 4 status for a specific property before recommending a route and drawing to the Royal Borough's guidance.
Typical Greenwich housing stock
Georgian and early-Victorian terraces around Royal Hill and Crooms Hill, the Victorian terraces of the Ashburnham Triangle, and the streets of West and East Greenwich framing the town centre and Greenwich Park.
Streets we regularly draw for in Greenwich
Royal Hill · Crooms Hill · Ashburnham Grove · Gloucester Circus
Flat Conversion Drawings for Greenwich (SE10) homes: the package and the process
Every flat conversion drawings we prepare for an Greenwich property is drawn to Royal Borough of Greenwich’s validation standards and tuned to the SE10 constraints above. Here is what the drawing package covers and how the process runs from first survey to approval.
Converting a house into flats is one of the few residential projects in London that always needs planning permission, whatever the size of the property or the number of units created. Splitting a single dwelling into two or more self-contained homes is treated as development regardless of whether any external work is proposed, because the change affects how the building is used and how many households occupy it.
DrawingsDirect draws house-to-flats conversions from the first survey through to a submission-ready planning and building-regulations package. Sound insulation between units, separate escape routes, individual services and London's minimum space standards are designed in from the layout stage, not retrofitted once the council asks for them — which is a large part of why our schemes are approved first time.
Do I need planning permission to convert a house into flats?
Yes, always. Converting a single dwelling into two or more self-contained flats is a change from one home to several, and that subdivision is treated as development requiring a full planning application — there is no permitted development route that allows it, regardless of the property's size or whether the exterior changes at all. The application has to demonstrate that each flat meets space, layout, amenity and parking standards in its own right, not just that the building as a whole is being used sensibly.
Boroughs also weigh the loss of a family-sized house against their local housing policy, since converting a larger house into several flats reduces the stock of homes suited to families even as it adds smaller units. We take that policy context into account when advising on layout and unit numbers, rather than simply maximising the number of flats the floor area could technically support.
What sound insulation is required between flats?
Part E of the building regulations sets minimum sound insulation standards for the walls and floors separating flats, covering both airborne and impact sound. Where an existing house is subdivided, the drawings specify how the party floors and walls between units will be upgraded — additional layers, resilient bars, or a floating floor — and pre-completion sound testing is normally required before the flats can be signed off. Getting this detail right on the drawings from the outset matters, because retrofitting sound insulation after a failed test usually means taking up a finished floor or ceiling that has already been decorated.
| Conversion | Typical scope | Route | Fee from |
|---|---|---|---|
| House to two self-contained flats | Vertical split, separate or shared entrance | Full planning plus building regulations | £1,600 |
| House to three or more flats | Multiple units, fire strategy required | Full planning plus building regs plus structural | £2,400 |
| Flat conversion with a side or rear extension | Additional floor area added to create compliant units | Full planning plus structural calculations | £2,800 |
Flat Conversion Drawings in Greenwich SE10 — FAQs
Do I need planning permission to convert a house into flats?+
How much do flat conversion drawings cost in London?+
What sound insulation is required between flats?+
Does each flat need a separate fire escape?+
What is the minimum size for a flat in London?+
Do I need planning permission for an extension in Greenwich?+
How does the Maritime Greenwich World Heritage Site affect my project?+
Can I extend a home in Blackheath or Westcombe Park?+
How long does the Royal Borough of Greenwich take to decide?+
How much do planning drawings cost in Greenwich?+
Get your free Greenwich planning assessment
Tell us your Greenwich (SE10) address and ambition — we'll confirm feasibility, local constraints and a fixed fee within one working day.